Swirl Vortex Flowmeter

Swirl Vortex Flowmeter
company Shanghai Sunny Instrument Co.,Ltd
Categories Flow Meters
Update2011-04-18
Original RegionChina
Swirl Vortex Flowmeter

Details

The Swirl flow meter provides all the advantages of the vortex flow meter by needing shortest upstream/downstream distances, typical 3 x DN/1 x DN. As the Vortex flow meter, the Swirl flow meter is based on the principle of Frequency measurement.The system has a freely configurable, LCD display for the actual flowrate and totalisation. Settings can be changed directly via 3 push buttons. Additional to the 4-20mA analog signal a freely configurable switching output is already available. This can be used universally as pulse output, high-low alarms or for system supervision. Swirl flow meter is available as compact or remote design with 10m cable length.
Size spectrum: DN 15 (1/2) to DN 200 (8) Accuracy: max.1.0 % or1.5 %of measured value for liquids, gases and steams.

High dynamic measuring range 1:25
Converter with most modern digital filter technology for the safe detection of also weakest sensor signals
Temperature sensor and pressure sensor are integrated for compensation. With latest design, Vibration will not have effect to the accuracy of the swirl flow meter.
Double swirl signal sensor.

Main technical parameters and functions
1 Flowmeter specification, basis parameter and performance index (refer to form 1)

DN(mm)

Style

Flow range(m3/ h)

Working pressure(Mpa)

Accuracy

Repeatability

15

0.3-20

1.6

2.5

4.0

6.3

1.0

1.5

Basis error less than absolute value limit 1/3

20

0.5-25

25

1.0~30

32

2.0~60

40

3.0~70

50

A

3.0~150

B

2.5~75

80

A

20~400

B

10~200

100

A

40~800

B

30~600

150

A

100~1800

B

40~900

200

180~3600

1.62.54.0

Note :(1).Accuracy: As temperature 、pressure of the system accuracy;
(2). A、B use the same distinction between different flow range.
2 Standard condition :P=101.325KPaT=293. 15K
3 Use condition :
Setting temperature30℃~+65℃
Relative humidity:5%~95%
Medium temperature:-20℃~+80℃
Barometric:86KPa~106KPa
4 Electrical performance index
4.1 Working source:
A. Outside source: +24VDC±15%, ripple<5%, apply to 4~20mA output, pulse output, alarm output, RS-485;
B. Inside sourceGroup 3.6V lithium battery(ER26500), when the voltage under 3.0V,there voltage instruction.
4.2 Power consumption:
A. Outside source2W;
B. Inside source: The average power consumption 1mW, can continuous use for more than two years.
4.3 Pulse output:
A.Working condition pulse signal, and direct the flow sensor detect condition pulse signal magnify output isolation Optocoupler, high ≥20V,low≤1V;High level, Low level
B.Calibration pulse signal, and IC card with valve control , extent≥2.8V,extent≤0.2V,pulse representative volume can set range: 0.001m3~100m3 .the value of single choice must pay attention to: calibration pulse signal frequency for≤900Hz .
C. Calibration pulse pulse signal magnify output isolation Optocoupler, high ≥20V,low≤1V.
4.4 RS-485 communication, (photoelectric insulation)and realize the following function :
A.Adopts RS-485 interface, can directly with transmitter or secondary form, transducer display the medium temperature, pressure and temperature, and pressure compensate after the standard volume flow and volume flow standard.
B.Assembled by RS-485 interface and LUXB-I data collector , can compose telephone networks system, and one data collector can take 15 flowmeters
C. Assembled by RS-485 interface and LUXB-II data collector, can compose broadband networks system, by INTERNET transmission data, and one data collector can take